Hospital Emergency Equipment Automated External Defibrillator Aed Biphasic Portable Defibrillator

Customization: Available
Application: Hospital
Type: Box

Product Description

📋 Basic Information
Model NO.
YJ-D9000
Product Name
Defibrillator
Display
7 Inches High-Resolution
Waveform
Biphasic
SpO2 Range
30~100%
Feature
Reusable
💻 Product Description

YJ-D9000 Defibrillator Monitor

Defibrillator Monitor

The YJ-D9000 is a professional biphasic defibrillator-monitor designed for emergency medical use.

  • Compact & Durable
  • Lightweight Design
  • Multi-parameter Monitoring
  • AED & Pacer Function
  • 5 Languages Choice
🔍 Core Features
SpO2 Module

SpO2 Module (Options)

Measurement Range: 30~100% (±2% between 80%~90%)
Alarm: User-set high/low limits
Accuracy: High precision within 12 sec response time.

ECG Monitoring

ECG Monitoring

Supports 3-lead or 5-lead ECG cables.
Display: I, II, AVR, AVL, AVF, V.
Heart Rate: 20-300 BPM.

NIBP Module

NIBP Module (Options)

Adult/Child/Neonatal modes available.
Systemic Pressure Range: 30~270 mmHg (Adult).
Accurate mean pressure tracking.

Technical Specifications
Category Parameter Details
DisplayScreen TypeHigh-resolution 8-inch display
Sweep Speed25mm/sec
InformationHR, Lead/Pads, SpO2, AED Prompts
DefibrillatorWaveformBiphasic
Charge TimeLess than 7 seconds (fully charged)
Energy DisplaySelected and delivered energy monitor
BatteryTypeRechargeable Ni-MH, 12V
Operating Time60 discharges or 3 hours ECG monitoring
📷 Detailed Photos
🏭 Production & Quality
Manufacturing Certification
Frequently Asked Questions
Q1: What type of waveform does the YJ-D9000 use?

A1: The YJ-D9000 utilizes a Biphasic waveform, which is the current clinical standard for effective defibrillation with lower energy levels.

Q2: How long does it take for the device to charge?

A2: With a new fully charged battery, the device can charge to maximum energy in less than 7 seconds.

Q3: Does the device support automated external defibrillation (AED)?

A3: Yes, it features an AED mode with programmable auto energy selection, voice prompts, and visual screen prompts.

Q4: What parameters can be monitored besides ECG?

A4: In addition to ECG monitoring (3-lead or 5-lead), the device offers optional modules for SpO2 (Pulse Oximetry) and NIBP (Non-Invasive Blood Pressure).

Q5: Is the display suitable for fast-paced medical environments?

A5: Absolutely. It features a high-resolution 8-inch diagonal display that provides clear visibility of Heart Rate, SpO2, and AED functions.

Q6: What is the battery capacity for mobile use?

A6: The rechargeable 12V Ni-MH battery provides enough power for 60 full-energy discharges or a minimum of 3 hours of continuous ECG monitoring.