Aed Automated External Defibrillator Monitor with LCD Display for Ambulance

Customization: Available
Classification: Biochemical Apparatus
Type: Defibrillator Monitor

Product Description

Basic Information
Model NO.GP-DM7000
CertificationCE, ISO13485
GroupAll People
Display8 Inch High Resolution LCD Display
Defibrillator WaveformBiphasic
ECG Size0.25, 0.5, 1, 1.5, 2, 4 Cm/Mv Display on Monitor
Recorder Paper50mm Thermal
Transport PackageStandard Export Cartons
SpecificationElectricity
Product Description
AED Monitor
External Defibrillator
Monitor Mode ECG measurement, SpO2 measurement (optional), NIBP measurement (optional), ETCO2 measurement (optional).
AED Mode Displays ECG value, adjusts defibrillation energy sequence, shows number of shocks, analysis results, and prints ECG waveforms.
Manual & Pacer Mode Adjustable energy from 2J-360J. Offers demand pacer and independent pacer mode with adjustable rates and output.
Convenient Printing One-click printing for monitoring information. Handle design for easy transfer in multiple environments.
General Specification
Size(L*W*H)330mm*240mm*180mm
WeightAbout 5.0kg
Power SupplyNI-MH 12V 3800mAh and AC power supply
Working Temp0°C ~ 40°C
Risk LevelDefib: BF Type; Monitor: ECG is CF Type
Defibrillation Parameter
WaveformBiphasic
Manual Energy2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J
AED Energy150J, 200J (Sequence Programmable)
Charging TimeLess than 8 seconds to maximum energy
Analysis Time7 Seconds
Product Gallery
Display Detail
Device View
Interface
Usage Scenario
Components
Full Set
Frequently Asked Questions
Q1: What waveform does the GP-DM7000 use? A1: It uses a Biphasic waveform for efficient and safe defibrillation.
Q2: How long does it take to charge to maximum energy? A2: The device reaches maximum charging energy in less than 8 seconds when the battery is in good condition.
Q3: Is the display suitable for emergency transport? A3: Yes, it features an 8-inch high-resolution LCD display and a handle design for convenient transfer.
Q4: What measurements are available in Monitor Mode? A4: Standard ECG measurement is included, with optional SpO2, NIBP, and ETCO2 measurements available.
Q5: Can this device be used in manual mode? A5: Yes, it supports manual defibrillation with energy levels ranging from 2J to 360J and also includes a Pacer mode.
Q6: What is the power source for the GP-DM7000? A6: It is powered by a NI-MH 12V 3800mAh battery and can also operate via AC power supply.